Our Inspection and Testing of Fire Alarm Systems Level I Exam study question has high quality. So there is all effective and central practice for you to prepare for your test. With our professional ability, we can accord to the necessary testing points to edit ITFAS-Level-1 exam questions. It points to the exam heart to solve your difficulty. With a minimum number of questions and answers of ITFAS-Level-1 test guide to the most important message, to make every user can easily efficient learning, not to increase their extra burden, finally to let the ITFAS-Level-1 exam questions help users quickly to pass the exam.
DOWNLOAD DEMO
A true simulation environment
Because many users are first taking part in the exams, so for the exam and test time distribution of the above lack certain experience, and thus prone to the confusion in the examination place, time to grasp, eventually led to not finish the exam totally. In order to avoid the occurrence of this phenomenon, the Inspection and Testing of Fire Alarm Systems Level I Exam study question have corresponding products to each exam simulation test environment, users log on to their account on the platform, at the same time to choose what they want to attend the exam simulation questions, the ITFAS-Level-1 exam questions are automatically for the user presents the same as the actual test environment simulation test system, the software built-in timer function can help users better control over time, so as to achieve the systematic, keep up, as well as to improve the user's speed to solve the problem from the side with our ITFAS-Level-1 test guide.
A brief introduction to the course
For most users, access to the relevant qualifying examinations may be the first, so many of the course content related to qualifying examinations are complex and arcane. According to these ignorant beginners, the ITFAS-Level-1 exam questions set up a series of basic course, by easy to read, with corresponding examples to explain at the same time, the Inspection and Testing of Fire Alarm Systems Level I Exam study question let the user to be able to find in real life and corresponds to the actual use of learned knowledge, deepened the understanding of the users and memory. Simple text messages, deserve to go up colorful stories and pictures beauty, make the ITFAS-Level-1 test guide better meet the zero basis for beginners, let them in the relaxed happy atmosphere to learn more useful knowledge, more good combined with practical, so as to achieve the state of unity.
Concise contents
The ITFAS-Level-1 exam questions by experts based on the calendar year of all kinds of exam after analysis, it is concluded that conforms to the exam thesis focus in the development trend, and summarize all kind of difficulties you will face and highlight the user review must master the knowledge content. And unlike other teaching platform, the Inspection and Testing of Fire Alarm Systems Level I Exam study question is outlined the main content of the calendar year examination questions didn't show in front of the user in the form of a long time, but as far as possible with extremely concise prominent text of ITFAS-Level-1 test guide is accurate incisive expression of the proposition of this year's forecast trend, and through the simulation of topic design meticulously.
NICET Inspection and Testing of Fire Alarm Systems Level I Sample Questions:
1. Inspection records for all systems shall be kept for which length of time?
A) 5 years
B) Until AHJ reviews records and 1 year
C) Until the next test and 1 year
D) 6 months
2. In addition to 10% of devices not affected, what else must be tested when site-specific software is changed?
A) 50% of devices affected
B) 100% of devices affected
C) 25% of devices affected
D) 10% of devices affected
3. Which three of the following branch circuit characteristics are required for circuit identification and accessibility of the fire alarm equipment's primary power supply? (Choose three.)
A) The system circuit disconnect shall be permanently identified at the control unit.
B) The system circuit disconnect shall be permanently identified as "Fire Alarm."
C) Where a circuit breaker is the disconnecting means, a breaker locking device shall be labeled.
D) Where a circuit breaker is the disconnecting means, a breaker locking device shall be installed.
4. With all notification appliances operating, what is the maximum sound pressure level, combined with the ambient sound pressure level, at the minimum hearing distance allowed by code?
A) 100 dBA
B) 105 dBA
C) 115 dBA
D) 110 dBA
5. How often are manual fire alarm boxes inspected?
A) Semiannually
B) Quarterly
C) Annually
D) Monthly
Solutions:
Question # 1 Answer: C | Question # 2 Answer: B | Question # 3 Answer: A,B,D | Question # 4 Answer: B | Question # 5 Answer: D |